# APC UPS APC MRTG config EnableIPv6: no WorkDir: /var/www/mrtg/ups YLegend[UPSNAME_1]: Hertz ShortLegend[UPSNAME_1]: Hz Directory[UPSNAME_1]: UPSNAME XSize[UPSNAME_1]: 400 YSize[UPSNAME_1]: 100 Legend1[UPSNAME_1]: Input Frequency Legend2[UPSNAME_1]: Output Frequency Legend3[UPSNAME_1]: Max Input Frequency Legend4[UPSNAME_1]: Max Output Frequency LegendI[UPSNAME_1]: Input Hz LegendO[UPSNAME_1]: Output Hz WithPeak[UPSNAME_1]: ywm MaxBytes[UPSNAME_1]: 100 Unscaled[UPSNAME_1]: dwmy Options[UPSNAME_1]: growright, gauge, nopercent Title[UPSNAME_1]: Input & Output Frequency Target[UPSNAME_1]: 1.3.6.1.4.1.318.1.1.1.3.2.4.0&1.3.6.1.4.1.318.1.1.1.4.2.2.0:COMMUNITYSTRING@IPADDRESS PageTop[UPSNAME_1]: <H1>Input & Output Frequency</H1> YLegend[UPSNAME_2]: Voltage ShortLegend[UPSNAME_2]: v Directory[UPSNAME_2]: UPSNAME XSize[UPSNAME_2]: 400 YSize[UPSNAME_2]: 100 Legend1[UPSNAME_2]: Input Voltage Phase 1 Legend2[UPSNAME_2]: Output Voltage Phase 1 LegendI[UPSNAME_2]: Input Voltage LegendO[UPSNAME_2]: Output Voltage WithPeak[UPSNAME_2]: ywm MaxBytes[UPSNAME_2]: 320 Unscaled[UPSNAME_2]: dwmy Options[UPSNAME_2]: growright, gauge, nopercent Title[UPSNAME_2]: Input and Output Voltage Phase 1 Target[UPSNAME_2]: 1.3.6.1.4.1.318.1.1.1.9.2.3.1.3.1.1.1&1.3.6.1.4.1.318.1.1.1.9.3.3.1.3.1.1.1:COMMUNITYSTRING@IPADDRESS PageTop[UPSNAME_2]: <H1>Input and Output Voltage Phase 1</H1> YLegend[UPSNAME_3]: Voltage ShortLegend[UPSNAME_3]: v Directory[UPSNAME_3]: UPSNAME XSize[UPSNAME_3]: 400 YSize[UPSNAME_3]: 100 Legend1[UPSNAME_3]: Input Voltage Phase 2 Legend2[UPSNAME_3]: Output Voltage Phase 2 LegendI[UPSNAME_3]: Input Voltage LegendO[UPSNAME_3]: Output Voltage WithPeak[UPSNAME_3]: ywm MaxBytes[UPSNAME_3]: 320 Unscaled[UPSNAME_3]: dwmy Options[UPSNAME_3]: growright, gauge, nopercent Title[UPSNAME_3]: Input and Output Voltage Phase 2 Target[UPSNAME_3]: 1.3.6.1.4.1.318.1.1.1.9.2.3.1.3.1.1.2&1.3.6.1.4.1.318.1.1.1.9.3.3.1.3.1.1.2:COMMUNITYSTRING@IPADDRESS PageTop[UPSNAME_3]: <H1>Input and Output Voltage Phase 2</H1> YLegend[UPSNAME_4]: Voltage ShortLegend[UPSNAME_4]: v Directory[UPSNAME_4]: UPSNAME XSize[UPSNAME_4]: 400 YSize[UPSNAME_4]: 100 Legend1[UPSNAME_4]: Input Voltage Phase 3 Legend2[UPSNAME_4]: Output Voltage Phase 3 LegendI[UPSNAME_4]: Input Voltage LegendO[UPSNAME_4]: Output Voltage WithPeak[UPSNAME_4]: ywm MaxBytes[UPSNAME_4]: 320 Unscaled[UPSNAME_4]: dwmy Options[UPSNAME_4]: growright, gauge, nopercent Title[UPSNAME_4]: Input and Output Voltage Phase 3 Target[UPSNAME_4]: 1.3.6.1.4.1.318.1.1.1.9.2.3.1.3.1.1.3&1.3.6.1.4.1.318.1.1.1.9.3.3.1.3.1.1.3:COMMUNITYSTRING@IPADDRESS PageTop[UPSNAME_4]: <H1>Input and Output Voltage Phase 3</H1> YLegend[UPSNAME_5]: Percent ShortLegend[UPSNAME_5]: % Directory[UPSNAME_5]: UPSNAME XSize[UPSNAME_5]: 400 YSize[UPSNAME_5]: 100 Legend1[UPSNAME_5]: Output Load Percent Legend2[UPSNAME_5]: Output Load Percent LegendI[UPSNAME_5]: Percent LegendO[UPSNAME_5]: Percent WithPeak[UPSNAME_5]: ywm MaxBytes[UPSNAME_5]: 100 Unscaled[UPSNAME_5]: dwmy Options[UPSNAME_5]: growright, gauge, nopercent Title[UPSNAME_5]: Output Load Percent Target[UPSNAME_5]: 1.3.6.1.4.1.318.1.1.1.4.2.3.0&1.3.6.1.4.1.318.1.1.1.4.2.3.0:COMMUNITYSTRING@IPADDRESS PageTop[UPSNAME_5]: <H1>Output Load Percent</H1> YLegend[UPSNAME_6]: Temperature ShortLegend[UPSNAME_6]: C Directory[UPSNAME_6]: UPSNAME XSize[UPSNAME_6]: 400 YSize[UPSNAME_6]: 100 Legend1[UPSNAME_6]: Internal UPS Temperature Legend2[UPSNAME_6]: Internal UPS Temperature LegendI[UPSNAME_6]: Celsius LegendO[UPSNAME_6]: Celsius WithPeak[UPSNAME_6]: ywm MaxBytes[UPSNAME_6]: 40 Unscaled[UPSNAME_6]: dwmy Options[UPSNAME_6]: growright, gauge, nopercent Title[UPSNAME_6]: Internal UPS Temperature Target[UPSNAME_6]: 1.3.6.1.4.1.318.1.1.1.2.2.2.0&1.3.6.1.4.1.318.1.1.1.2.2.2.0:COMMUNITYSTRING@IPADDRESS PageTop[UPSNAME_6]: <H1>Internal UPS Temperature</H1> YLegend[UPSNAME_7]: Temperature ShortLegend[UPSNAME_7]: C Directory[UPSNAME_7]: UPSNAME XSize[UPSNAME_7]: 400 YSize[UPSNAME_7]: 100 Legend1[UPSNAME_7]: External UPS Temperature Legend2[UPSNAME_7]: External UPS Temperature LegendI[UPSNAME_7]: Celsius LegendO[UPSNAME_7]: Celsius WithPeak[UPSNAME_7]: ywm MaxBytes[UPSNAME_7]: 40 Unscaled[UPSNAME_7]: dwmy Options[UPSNAME_7]: growright, gauge, nopercent Title[UPSNAME_7]: External UPS Temperature Target[UPSNAME_7]: 1.3.6.1.4.1.318.1.1.10.2.3.2.1.4.1&1.3.6.1.4.1.318.1.1.10.2.3.2.1.4.1:COMMUNITYSTRING@IPADDRESS PageTop[UPSNAME_7]: <H1>External UPS Temperature</H1> YLegend[UPSNAME_8]: Percent ShortLegend[UPSNAME_8]: % Directory[UPSNAME_8]: UPSNAME XSize[UPSNAME_8]: 400 YSize[UPSNAME_8]: 100 Legend1[UPSNAME_8]: Battery Charge Level Legend2[UPSNAME_8]: Battery Charge Level LegendI[UPSNAME_8]: % LegendO[UPSNAME_8]: % WithPeak[UPSNAME_8]: ywm MaxBytes[UPSNAME_8]: 100 Unscaled[UPSNAME_8]: dwmy Options[UPSNAME_8]: growright, gauge, nopercent Title[UPSNAME_8]: Battery Charge Level Target[UPSNAME_8]: .1.3.6.1.4.1.318.1.1.1.2.2.1.0&.1.3.6.1.4.1.318.1.1.1.2.2.1.0:COMMUNITYSTRING@IPADDRESS PageTop[UPSNAME_8]: <H1>Battery Charge Level</H1> |